Product ID: PE-148 PE-148N PE-149G ORP-148G         
pH Electrode ORP Electrode ( PE-148 PE-148N PE-149G ORP-148G)
A wide variety of Tecpel pH electrodes in the result of continuing Research and Development in this technology.

The pH sensitive glass membrance of electrodes has extremely low alkaline error and low electrical resistance thus
ensuring fas and accurate response. We can supply these electrodes for pH range of 0 14 and for temprature range of
0~  0 ~ 80 °C  and 0~ 100 C.

Electrode are available in Gel, KCl filled versions and are supplied with 1 meter long cable and BNC plug. Longer
cable lengths can be supplied at an extra cost. These electrodes can be supplied with almost all makes of int'l and
domestic pH meters.

We follow well defined strict quality control measures and each and every electrode is checked individually for its
performance and quality by our Q.C. Department.
Model                   Range                   Temperature        Body        Refillable
PE-148              0 ~ 14 pH                    0 ~ 80 °C          PC             Yes
PE-148N          0 ~ 14 pH                     0 ~ 80 °C          PC              No
PE-149G          0 ~ 14 pH                     0 ~ 80 °C         Glass        Yes
ORP-148G        ± 1500 mV                  0 ~ 80 °C         Glass        Yes



Specifications:
•        PE-148
Range: 0 ~ 14 pH
Temperature: 0 ~ 80 C
Type Ref.: Ag/Agcl
Junction: Ceramic
Refillable: Yes
Body : PC
Connector: Regular BNC
Body Size: 160 mm
Cable Length: 1 M

•        PE-148N
Range: 0 ~ 14 pH
Temperature: 0 ~ 80 C
Type Ref.: Ag/Agcl
Junction: Ceramic
Refillable: No.
Body : PC (Gel filled type)
Connector: Regular BNC
Body Size: 160 mm
Cable Length: 1 M

•        PE-149G
Range: 0 ~ 14 pH
Temperature: 0 ~ 80 C
Type Ref.: Ag/Agcl
Junction: Ceramic
Refillable: Yes
Body : Glass
Connector: Regular BNC
Body Size: 160 mm
Cable Length: 1 M

•        ORP-148G
Range: +/- 1500mV
Temperature: 0 ~ 80 C
Type Ref.: Ag/Agcl
Junction: Ceramic
Refillable: Yes
Body : Glass
Connector: Regular BNC
Body Size: 160 mm
Cable Length: 1 M









Q & A:

Are ORP and PH probes that Tecpel supply us (with the BNC connectors) suitable
for continuous submersion in a Salt water marine fish tank, With periodic
cleaning of course.

Ans: We have some dealers and OEM’s who are selling in that market & hence I think they can absolutely be used.







Ordering Information:
pH Electrode :  PE-148 PE-148N PE-149G
ORP Electrode : ORP-148G

Minimum Order: Negotiable
TEL: 886-2-27375866
FAX: 886-2-27373343
E-mail:  sales@tecpel.net
http://www.tecpel.net
http://www.tecpel.com
TECPEL CO., LTD.
ORP ELECTRODE  ORP-148G