Product ID: DTM-3103

Pocket Thermometer ( DTM-3103)
Digital Multi-Thermometer
With 1 meter Sensor Probe
Model : DTM-3103 Function
ON/OFF, H/T, MAX/MIN (°F/°C) MEMORY RECALLING
°F/°C & HI/LOW ALARM FUNCTION


Features
  • One Hour Auto Shut Off
  • 133mm  Stainless Steel Sensor Probe
  • Protective Plastic Cap for Stainless Steel
  • With stand on back unit and sensor wire compartment
  • MAX/MIN (°F/°C) Memory Recalling
  • Alarm Beep sound at the high or low
  • Temperature limited
  • Temperature Unit  °F/°C Selectable
  • DATA HOLD/Test Function Selectable
  • Low Battery Indicator
  • 1 Sec. Normal Temperature Sensing Time

Specification:
Measurement Range:  
-50°C ~ +150°C or -58°F ~+302°F

Resolution : 0.1° FOR -19.9° ~ +199.9°, Otherwise 1°

Accuracy :
±1°C in the range of -30°C ~ +150°C
±1.8°F In the range of  of -22°F ~ +302°F


Ambient Temperature for plastic Casing:
-10°C ~ +50°C OR +14°F ~ +122°F
Battery : 1 X 1.5V "A76" Size(LR44,G13) or equivalent




INSTALLATION:
UNPACK THE THERMOMETER WITH CARE.
OPEN THE BATTERY DOOR. THEN FULLY EXTEND THE PROBE CABLE. INSTALL ONE "A76" SIZE
(OR EQUIVALENT) BATTERY INTO THE BATTERY COMPARTMENT AND CLOSE THE BATTERY
DOOR.

TAKE OFF THE PROBE CAP FROM THE PROBE TIP, THE THERMOMETER IS NOW READY FOR
USE.
REPLACE NEW BATTERY WHEN THE LOW BATTERY INDICATOR APPEARS ON THE SCREEN.
OPERATION:
OPERATION:
PRESS THE "ON/OFF" BUTTON. ALL FUNCTIONS WILL SHOW ON THE DISPLAY. THE
THERMOMETER IS READY FOR USE.
PRESS THE "°C/°F" BUTTON TO SELECT DESIRED TEMPERATURE UNIT. IT WILL CHANGE
IMMEDIATELY.
PRESS THE "HOLD/TEST" BUTTON TO "TEST" POSITION FOR TEMPERATURE MEASUREMENT
OR "HOLD" POSITION TO RETAIN READING FOR RECORDING. THE WORD "HOLD" WILL FLASH
ON THE DISPLAY TO INDICATE THE HOLDING POSITION.
PRESS THE "MAX / MIN" BUTTON. "MIN" SIGN WILL BE SHOWN. THE MINIMUM TEMPERATURE
TESTED WILL DISPLAY. PRESS THE BUTTON AGAIN. "MAX" SIGN WILL BE SHOWN. THE MAXIMUM
TEMPERATURE TESTED WILL DISPLAY. IT WILL GO BACK TO THE TESTING POSITION
AUTOMATICALLY AFTER THREE SECONDS.
TEMPERATURE ALARM SETTING:
TEMPERATURE ALARM SETTING:
PRESS AND HOLD THE "LOW ALARM" OR "HI ALARM" BUTTON FOR SETTING ALARM AT DESIRED
MINIMUM OR MAXIMUM TEMPERATURE LIMIT. THE DISPLAY WILL SHOW -50°C OR -58°F AND
START TO
INCREASE UP TO +150°C OR +302°F / +299°C OR +570°F DEPENDING ON THE AVAILABLE
MEASUREMENTRANGE.
RELEASE THE "LOW ALARM" OR "HI ALARM" BUTTON WHEN THE DESIRED TEMPERATURE
ISAPPROACHED. THE DISPLAY VALUE WILL STOP INCREASING.
AFTER RELEASING THE BUTTON FOR APPROXIMATELY 3 SECONDS THE THERMOMETER WILL
RETURN TO THE TESTING MODE. "LO" OR/AND "HI" SIGN WILL DISPLAY. THE ALARM WILL
SOUND 4 BEEPS PER MINUTE WHEN THE MEASURED TEMPERATURE EQUALS OR IS GREATER
THAN THE MAXIMUM TEMPERATURE OR
LESS THAN THE MINIMUM SET VALUE.
TO STOP BEEPING, PRESS ANY BUTTON.
TO DELETE THE ALARM SET, PRESS "°C/°F" OR "ON/OFF" BUTTON.
PRECAUTIONS:
PRECAUTIONS:
TO OBTAIN THE BEST RESULTS, THE PROBE TIP SHOULD BE IMMERSED AT LEAST 10MM. INTO
THE TESTED SUBSTANCE.
REMOVE THE BATTERY FROM THE BATTERY COMPARTMENT IF THE THERMOMETER WILL NOT
BE USED FOR LONG DURATION OF TIME OR DURING STORAGE.
THE THERMOMETER CANNOT BE USED OR PUT INSIDE ANY OVEN OR MICROWAVE.














Ordering Information:
DTM-3103 Stem Thermometer



Minimum Order: Negotiable
TEL: 886-2-27375866
FAX: 886-2-27373343
E-mail:  sales@tecpel.net
http://www.tecpel.net
TECPEL CO., LTD.
Share by: